Dengan enjin Cummins KTA50-GS8, harga penjana 1200kw, penjana diesel 1200 kw
Barang No.:
AC1825Pesanan(MOQ):
1Bayaran:
T/T 30%, 70% or LC 100% at sight.Asal Produk:
ChinaWarna:
White, yellow, green, blue etc colors for choicePelabuhan Penghantaran:
Xiamen, ChinaMasa Utama:
3-4 weeksTentang kita
Pengenalan Kilang Kuasa AI
Unit kuasa berkualiti tinggi, boleh dipercayai dan lengkap
Reka bentuk padat
Kemungkinan permulaan dan penyelenggaraan yang mudah
Setiap set penjanaan tertakluk kepada program ujian komprehensif yang merangkumi ujian beban penuh, pemeriksaan dan penyediaan semua ujian fungsi penutupan kawalan dan keselamatan
Kejuruteraan sepenuhnya dengan pelbagai pilihan dan aksesori: Kanopi, kanopi kalis bunyi dan treler di jalan raya
Butiran penjana diesel | |
Model | CLK-1500GF |
Kuasa | 1500kva |
Kekerapan | 50HZ |
voltan | 380/220v (voltan boleh disesuaikan) |
Jenis Pilihan | Terbuka/kalis bunyi/treler |
Saiz jenis Terbuka | 12000*2400*2900mm |
Berat jenis Terbuka | 10300kg |
Dengan Enjin Diesel | |
Jenama&model | Cummins KTA50-GS8 |
Kuasa Siap Sedia | 1200kw |
Cylinders | V-16 |
Bore*Stroke | 159*159mm |
Displacement | 50L |
Lubrication Oil Capacity | 135L |
Fuel Consumption at 100% Load | 204g/kw.h |
Speed Governor | Electric |
With Alternator | |
Optional Brands | Stamford/Leroy Somer/Hengsheng/Marathon |
Exciter type | Single bearing,brushless,Self-excited |
Power factor | 0.8 |
Voltage adjust range | ≥5% |
Insulation Grade | H |
Protection Grade | IP23 |
With Controller | |
Optional brands | Deepsea/ComAp/Smartgen |
RFQ:
Generator set grounding system
In order to ensure personal safety and the needs of power system work, there are strict requirements for 1 mega power generator grounding.
There are three grounding modes: working grounding, protective grounding and protective neutral grounding. The purpose of grounding is as follows:
1. Working grounding
Working grounding is to ground the neutral point, and its purpose is to:
1) Reduce the electric shock voltage. For the system with ungrounded neutral point, when one phase is grounded and the human body touches one of the other two phases, the medium voltage is more than 1.7 times of the phase voltage; For neutral grounding system, the electric shock voltage drops to close to or equal to phase current
2) Quickly cut off the faulty equipment. For the system with ungrounded neutral point, when one phase is grounded, the current path can be formed due to the capacitance and insulation resistance between the conductor and the ground. The grounding current is very small, which is not enough to make the protective device act and cut off the power supply, so as to ensure personal safety. For the neutral grounded system, when one phase is grounded, the grounding current is large, and the protection device will act quickly to disconnect the fault point.
3) Reduce the insulation level of electrical equipment to ground. In a neutral ungrounded system, when one phase is grounded, the ground voltage of the other phase C will rise to the line voltage. For the neutral grounded system, when one phase is grounded, the other two phases are only close to the phase voltage, so the insulation level of electrical equipment and transmission line can be reduced.